HYBO CS Buck mode | HYBRID HYBO BUILT IN TRANSFORMER | |||
PV Buck Mode | ||||
Model | CS100 | CS150 | CS250 | CS500 |
On Grid AC specifications | ||||
Max. Output power (kVA) | 110 | 165 | 275 | 550 |
Rated Output Power (kW) | 100 | 150 | 250 | 500 |
Rated Voltage (V) | 400 | |||
Voltage Range (V) | 320~460 | |||
Rated Current (A) | 144 | 216 | 361 | 722 |
Rated Frequency (Hz) | 50 / 60 | |||
Frequency Range (Hz) | 45~55 – 55~65 | |||
THDi | <3% | |||
Power Factor | 1 lagging – 1 leading (Settable) | |||
AC Connection | 3W+N+PE | |||
Transformer Ratio | 270 / 400 | 270 / 400 | 270 / 400 | 315 / 400 |
Model | CS100 | CS150 | CS250 | CS500 |
Off Grid Specifications | ||||
Max. Output Power (kVA) | 110 | 165 | 275 | 550 |
Rated Power (kW) | 100 | 150 | 250 | 500 |
Rated Voltage (V) | 400 | |||
Rated Current (A) | 144 | 216 | 361 | 722 |
THDU | ≤1% linear; or ≤5% nonlinear | |||
Rated Frequency (Hz) | 50 / 60 | |||
Overload Capacity | 110% Continuous / 150% 10 sec | |||
On to Off-grid Transfer Time | 13ms | |||
Model | CS100 | CS150 | CS250 | CS500 |
High Voltage PV Input ( Buck Mode) | ||||
PV Input Voltage Range (Voc)(V@25°C) | 655-900 | 780-900 | ||
Max. PV Power (kW) MPPT in step of 60kW | 120 / 180 / 240 | 120 / 180 / 240 | 300 / 360 | 600 / 660 / 720 |
MPPT Voltage Range(V@25°C) | 544-747 | 648-747 | ||
buck mode Battery | ||||
Battery Voltage Range (V) | 420-672 | 500-672 | ||
Battery cabinet Composition | Min 8 Max 12 Batteries | Min 9 Max 12 Batteries | ||
Max. Charging Power (kW) | 120 / 180 / 240 | 120 / 180 / 240 | 300 / 360 | 600 / 660 / 720 |
Model | CS100 | CS150 | CS250 | CS500 |
General Data | ||||
Max On and Off grid parallel Units | 10 | |||
Dimension W*D*H (mm) | 1200*800*2050 | 1200*800*2050 | (600*720*2050) *1+1200*800*2050 | (600*720*2,050) *2+1600*1050*2050 |
Weight (kg) | 1120 / 1150 / 1180 | 1250 / 1280/1310 | 1980 / 2010 | 3265/3295/3325 |
Operation Temperature (℃) | -30~55 | |||
Relative Humidity | 0~95% non-condensing | |||
IP Rating | IP20 | |||
Noise Emission (dB) | <70 | |||
Altitude | 4,000m (>3,000 Derating) | |||
Cooling | Forced Air Cooling | |||
Display and Communication | ||||
Display | LCD touch-screen / NooR Smart App | |||
BMS Communication | RS485, CAN | |||
EMS Communication | RS485, TCP/IP | |||
Standards | EN62109-1/-2, EN62447-1, EN61000-6-2, EN61000-6-4, South Africa NRS097-2-1:2017, Pakistan & India IEC62116, IEC61683 |
See warranty for performance warranty applicability.
See Performance Warranty Terms and the Standard Test Conditions “STC”.
All data is subjected to change without prior notice: Always ask WeCo for the most recent datasheet and manual before purchasing.